Components specification
Vacuum generation block
- n° 2 liquid ring ( anello liquido ) vacuum pumps
- aspiration flow rate: 200mc/h at 213 mbar
- installed power: 5,5 kw with 4 poles
- n° 1 recycling water tank made of zinc plated steel, painted, 300 litres capacity, with upper inspection flanging
|
 |
Liquid collection and discharge tank
Preset for direct lying underground, sized to resist to an internal depression of – 100Kpa, entirely made of stainless steel AISI304, with the following features:
- Capacity: 7mc
- Diameter: 2360 mm
- Thickness: 6 mm
- Height: 2100 mm
N° 2 underwater electro pumps with the following features:
- Flow rate: 8 l/sec.
- Head: 10 m.c.a.
- Power: 2,4 kw. |
 |
Depression pipelines
The pipelines net are always under a constant internal level or relative negative pressures of about – 40/-70 kPa (-4/-7 m.c.a.).
The vacuum pipelines create a completely sealed circuit; the material used is high density polyethylene (PEAD) PN6-10, with specific accessories that grant operationality to the implant.
The high density polyethylene's flexibility grants the realization of the project profile without any special additional parts.
|
 |
Interface traps
- capacity: about 600 litres
- flow rate: 120 l/cycle (adjustable)
- material: PEAD
- curb box: spheroidal cast iron D400 UNI-EN 124 class
- size: int. Diameter 700 mm, height 1500 mm.
- users drainage: N° 3 antiextraction joints D= 125 mm
- vacuum net: N° 1 pipe D= 75 mm
Pneumatic components
- PVC PN10 aspiration block
- D63 mm – 2” pneumatic valve
- floating activator
Operational conditions
It's good to estimate during the sizing process that a trap works an aspiration cycle every hour (120 litres x 24 cycles/day) for a total flow of 2900 l/day, for this reason the project will consider a trap every 12.5 inhabitants (2900 l/day : 230l/inhabitant) |
|
|
|